Skip to main content

Buttons and Indicators

Button Operations

ButtonShort PressLong Press
Channel 0 ForwardStart or stop Channel 0 forward movementForce Channel 0 to move forward; stops when released
Channel 0 ReverseStart or stop Channel 0 reverse movementForce Channel 0 to move backward; stops when released
Channel 1 ForwardStart or stop Channel 1 forward movementForce Channel 1 to move forward; stops when released
Channel 1 ReverseStart or stop Channel 1 reverse movementForce Channel 1 to move backward; stops when released
Status ButtonSwitch between loading/automatic modeHold for about 2 seconds to perform sensor calibration
Forced Movement

Long-pressing the button temporarily ignores normal sensor edge-stop conditions and is used only to clear the material path when sensor anomalies occur. Ensure the material path is unobstructed before operating, and keep fingers and tools away from the gripping points, feeding wheels, and motors. Even after releasing the button, verify that the mechanism has stopped; do not use it for extended periods during printing.

Device Modes

ModeStatus ButtonPurpose
Loading ModeRedManual loading, unloading, maintenance, and troubleshooting
Automatic ModeGreenAutomatic feeding and refilling based on buffer position

A short press of the status button switches between the two modes. After switching, observe the status light first, then conduct single-channel tests.

Channel Indicators

Light PatternMeaning
Red or red pulsingNo consumables in the channel
Green or green pulsingConsumables detected in the channel
Green blinkingChannel is in active operation
Yellow blinkingChannel moving forward via button control
Blue blinkingChannel moving backward via button control

Status Button

The status button is used to switch between loading/automatic modes and initiate sensor calibration; details on the buzzer alert are provided in the “Buzzer” section below.

Power-Off Operation

Before checking the material path, wiring harness, terminals, or sensor installation as listed, fully turn off the printer and disconnect the power supply. Do not plug or remove the wiring harness or touch the terminals while the device is powered on.

Light PatternMeaningRecommended Action
GreenAutomatic ModeUse after confirming the buffer and material path are functioning properly.
RedLoading ModeUsed for manual loading, unloading, or troubleshooting.
White blinkingNot yet calibratedPerform sensor calibration after clearing the material path.
Red, green, blue cyclingCalibrating or saving calibration dataWait for the light pattern to end; do not power off or operate the motor.
Red fast blinkingMotion timeout or error conditionStop feeding and check the material path and sensors with power off.
Purple or purpleishPossible issues with sensor wiring, installation, or input statusStop automatic feeding and check the wiring harness and sensor installation with power off.

Calibration and error light patterns take precedence over normal mode light patterns. If an alarm persists, check the material path and sensors first; do not bypass the alarm by disabling protections.

Buzzer

The buzzer only provides audible alerts and does not affect the mode switching or calibration functions of the status button. If the beep parameter in the tool is set to 0, the device may not emit the following sounds.

Sound AlertMeaningRecommended Action
Short beeps repeated in cyclesMaterial shortage in the corresponding channelVerify that consumables have reached the inlet sensor position.
Short, short, short, longMotion timeout or distance protection triggeredStop feeding and follow the troubleshooting procedures; do not disable protections.
Loading...