Skip to main content

Wiring and Configuration

Wiring Instructions​

Loading...
K-type thermocouples have positive and negative poles

When wiring a K-type thermocouple, pay attention to the positive and negative polarity: the red wire is the positive pole (+), and the gray/white wire is the negative pole (-). Reversing the connection will cause abnormal temperature readings or prevent acquisition.

Klipper Reference Configuration​

UART as sensor_pin (left side)​

[temperature_sensor left]
sensor_type: MAX6675
sensor_pin: PA7
spi_bus: spi1a
spi_speed: 100000

EN as sensor_pin (right side)​

[temperature_sensor right]
sensor_type: MAX6675
sensor_pin: PE10
spi_bus: spi1a
spi_speed: 100000
Caution

The above sensor_pin and spi_bus are example values. Please modify them according to the pin definitions and SPI bus of the motherboard you are actually using.

More thermistor configuration methods: Thermistor Configuration Methods

Loading...