Pause and Cancel Print Custom Position
- Need to add
[include mainsail.cfg]
or[include fluidd.cfg]
inprinter.cfg
- Add the macro below to
printer.cfg
Chinese Translation
[gcode_macro _CLIENT_VARIABLE]
### Custom settings related to pause macro
variable_use_custom_pos : False ; Whether to use custom docking coordinates x, y [True/False]
variable_custom_park_x : 0.0 ; X position when pausing print
variable_custom_park_y : 0.0 ; Y position when pausing print
variable_custom_park_dz : 2.0 ; Distance (in mm) to raise the Z-axis when pausing print
### Custom settings related to unpause/cancel macro
variable_park_at_cancel : False ; Whether to allow moving the toolhead to the parking position when executing the cancel print macro [True/False]
variable_park_at_cancel_x : None ; X position after print cancellation
variable_park_at_cancel_y : None ; Y position after print cancellation
### Actions for extruder on pause and cancel
variable_retract : 1.0 ; Retraction length when pausing print (mm)
variable_cancel_retract : 5.0 ; Retraction length when cancelling print (mm)
variable_speed_retract : 35.0 ; Retraction speed in mm/s
variable_unretract : 1.0 ; Extrusion length when resuming print
variable_speed_unretract : 35.0 ; Extrusion speed in mm/s
variable_speed_hop : 15.0 ; Z-axis movement speed in mm/s
variable_speed_move : 100.0 ; Movement speed in mm/s
### Motor and heater shutdown settings
### One day equals 86400 seconds
variable_idle_timeout : 0 ; Seconds until idle timeout starts. Setting to 0 means no value will be set or restored
# !!!Note: If you set use_fw_retract: True, you must define [firmware_retraction] in printer.cfg!!!
variable_use_fw_retract : False ; Whether to use firmware retraction instead of manual version [True/False]
variable_runout_sensor : "" ; If defined, this sensor will be used to cancel the RESUME command if no filament is detected.
# Specify the configuration name of the sensor, e.g. "filament_switch_sensor runout". Reminder: Use the same name as in your printer.cfg
# !!!Custom macros, please use with caution and check the relevant macro section. These macros are intended for simple operations like setting status LEDs. Ensure your macros don't interfere with basic macro functionality. Only single line commands are supported. If you need multiple commands, create a separate macro.
variable_user_pause_macro : "" ; Everything inside "" will be executed after Klipper's base pause (PAUSE_BASE) function
variable_user_resume_macro: "" ; Everything inside "" will be executed before Klipper's base resume (RESUME_BASE) function
variable_user_cancel_macro: "" ; Everything inside "" will be executed before Klipper's base cancel (CANCEL_PRINT_BASE) function
gcode:
English (Original)
[gcode_macro _CLIENT_VARIABLE]
variable_use_custom_pos : False ; use custom park coordinates for x,y [True/False]
variable_custom_park_x : 0.0 ; custom x position; value must be within your defined min and max of X
variable_custom_park_y : 0.0 ; custom y position; value must be within your defined min and max of Y
variable_custom_park_dz : 2.0 ; custom dz value; the value in mm to lift the nozzle when move to park position
variable_retract : 1.0 ; the value to retract while PAUSE
variable_cancel_retract : 5.0 ; the value to retract while CANCEL_PRINT
variable_speed_retract : 35.0 ; retract speed in mm/s
variable_unretract : 1.0 ; the value to unretract while RESUME
variable_speed_unretract : 35.0 ; unretract speed in mm/s
variable_speed_hop : 15.0 ; z move speed in mm/s
variable_speed_move : 100.0 ; move speed in mm/s
variable_park_at_cancel : False ; allow to move the toolhead to park while execute CANCEL_PRINT [True/False]
variable_park_at_cancel_x : None ; different park position during CANCEL_PRINT [None/Position as Float]; park_at_cancel must be True
variable_park_at_cancel_y : None ; different park position during CANCEL_PRINT [None/Position as Float]; park_at_cancel must be True
# !!! Caution [firmware_retraction] must be defined in the printer.cfg if you set use_fw_retract: True !!!
variable_use_fw_retract : False ; use fw_retraction instead of the manual version [True/False]
variable_idle_timeout : 0 ; time in sec until idle_timeout kicks in. Value 0 means that no value will be set or restored
variable_runout_sensor : "" ; If a sensor is defined, it will be used to cancel the execution of RESUME in case no filament is detected.
# Specify the config name of the runout sensor e.g "filament_switch_sensor runout". Hint use the same as in your printer.cfg
# !!! Custom macros, please use with care and review the section of the corresponding macro.
# These macros are for simple operations like setting a status LED. Please make sure your macro does not interfere with the basic macro functions.
# Only single line commands are supported, please create a macro if you need more than one command.
variable_user_pause_macro : "" ; Everything inside the "" will be executed after the klipper base pause (PAUSE_BASE) function
variable_user_resume_macro: "" ; Everything inside the "" will be executed before the klipper base resume (RESUME_BASE) function
variable_user_cancel_macro: "" ; Everything inside the "" will be executed before the klipper base cancel (CANCEL_PRINT_BASE) function
gcode:
Loading...