Fan Reference Configuration
Drive Fan
-
There are two configuration methods for the drive fan
-
The first is to configure it yourself, and the motor works when it starts
-
The second is to run directly upon boot
-
First method
-
The exclamation mark in front reverses the fan port state, making it work when connected to Klipper
[output_pin driver_fan]
pin: !PF7
- Second method
[controller_fan driver_fan] # Driver cooling fan
pin:
cycle_time: 0.00003 # Cycle time
max_power: 1.0 # Maximum power
shutdown_speed: 0.0 # Shutdown speed
fan_speed: 0.9 # Fan speed when heater or stepper driver is active (0.0 to 1.0). Default is 1.0.
idle_timeout: 90 # Time in seconds to keep the fan running after the stepper driver or heater is no longer active. Default is 30 seconds.
idle_speed: 0.4 # Fan speed after the stepper driver is no longer active and before idle_timeout is reached (0.0 to 1.0). Default is fan_speed.
stepper: stepper_x # Active motors
#Define the name of the heater/stepper configuration section associated with this fan.
#If a comma-separated list of heater/stepper names is provided here, the fan will be enabled when any of the given heaters/steppers are enabled.
#The default heater is "extruder", and the default stepper is all steppers.
7040 Fan
- Mainly introduces the solution for the fan to start rotating upon boot
info
- This is a simple explanation
- Add the PWM signal pin during firmware compilation and reverse its state
- Tested with SUPER8PRO, using pin PF8, during firmware compilation select
GPIO pins to set at micro-controller startup
and enter!PF8
- Please note that the entered
!
is an English exclamation mark - Other mainboards are similar

[fan]
## Print Cooling Fan
pin:
max_power: 0.9
cycle_time: 0.002
hardware_pwm: false
shutdown_speed: 0