Machine Debugging Guide
Notes
- This article applies to printers that have completed basic assembly and are ready for initial debugging.
- It is recommended to follow the order below to avoid skipping safety checks that could cause crashes or heating abnormalities.
- When involving wiring, endstops, or power supply checks, please power off before operating.
First Choose Your Task
| What to do now | Recommended entry | Configuration purpose |
|---|---|---|
| Select boards and multiple interfaces to quickly generate test configurations | Klipper Quick Test | Temporary configuration, only for isolated interface verification |
| Determine test results for temperature, output, input, or accelerometer | Hardware Testing Methods | Operating steps, normal results, and exception handling |
| Check driver communication, motors, or CAN tool boards | Peripherals and Driver Testing | Minimal hardware troubleshooting |
| Hardware confirmed normal, ready for first full machine debugging | Follow the order below | Formal printer configuration |
| Configuration cannot load or format errors occur | Configuration Modification Guide | Resolve configuration issues first, then test |
Temporary testing is not the same as full machine debugging
The kinematics: none configuration generated by quick testing is not for homing, leveling, or printing. Back up your formal configuration first; after testing is complete, turn off outputs, disable test motors, and restore the formal configuration, then check endstop status and movement direction. Do not directly overlay test sections onto a formal configuration that already occupies the same pins.
Debugging Steps
| Step | Content | Description |
|---|---|---|
| Step 1 | Power Wiring Instructions | Host power supply requirements, recommended power supply methods, ensuring correct power supply |
| Step 2 | Endstop Check | Check endstop wiring and trigger status, ensure hardware is correct before homing |
| Step 3 | Homing and Direction Calibration | Motor wiring check, single-axis homing test, CoreXY direction calibration |
| Step 4 | Heating and Temperature Calibration | Check heating function, PID temperature calibration, heating abnormality troubleshooting |
| Step 5 | Machine Calibration | Extruder rotation_distance calibration, Z offset calibration |
| Step 6 | Macro Configuration | Start macro, end macro configuration, slicer settings |
| Step 7 | Configuration Modification Guide | Common configuration format errors and troubleshooting methods |
Division of Labor Between Tools and Troubleshooting
- Quick test tools are responsible for generating configurations and do not replace physical board verification, jumper checks, and wiring checks; after merging multiple test items, commands must still be executed one by one.
- The two hardware testing documents retain general examples, result judgment, and fault troubleshooting; do not directly copy example pins for different board types.
- This guide is responsible for full machine debugging under formal configuration. When a single interface abnormality is found, you can switch to hardware testing; after troubleshooting is complete, return to the current step.
- Heating and PID must use complete temperature control and protection configurations; ordinary
output_pinmust not be used to drive heating loads.
Extended Features
| Content | Description |
|---|---|
| Sensorless Homing | For machines without physical endstop switches, use driver sensorless homing |
| Common Debugging Commands | Quick reference for common Klipper console debugging commands |
| LED Warning Light | Three-color warning light wiring and status macro configuration |
Advanced command supplement: Advanced Debugging Commands. Please confirm the applicable conditions of commands first, and do not treat the command quick reference as a script that can be executed in batches.
Loading...