Peripheral and Driver Testing

This page is used to verify whether peripheral modules such as stepper drivers and CAN toolhead boards are working properly. The testing approach is the same as basic I/O testing, using a minimal Klipper configuration to isolate a single piece of hardware.

If you need to test MCU connection, temperature sensors, fan outputs, or input ports, please refer to Hardware Testing Methods first.

Configuration Generation and Testing Steps

Use Klipper Quick Test to select drivers or other interfaces by board and add them to the test list; this page is used to verify wiring, execution order, and result interpretation. For basic preparation, see Hardware Testing Methods; when done, return to the Machine Commissioning Guide.

Driver Testing​

Test Purpose​

Use the simplest Klipper configuration to verify whether a single TMC driver (UART or SPI mode) can communicate properly with the mainboard, and confirm that the motor can be controlled.

Prerequisites​

Power-Off Operation

Please fully shut down the printer and disconnect the power supply before performing the following operations. Do not plug or unplug driver modules or stepper motor cables while powered on.

  1. The printer is fully powered off.
  2. For pluggable drivers, confirm the insertion orientation; onboard fixed drivers must not be removed or replaced with a different model—configure according to the actual board model.
  3. If using a UART mode driver (such as TMC2209), confirm that the UART jumper cap for the corresponding driver port is installed.
  4. Connect A the stepper motor to the driver port under test, and leave the other driver ports empty for now.
  5. Back up the original complete configuration file, and prepare a temporary printer.cfg containing only the basic minimal configuration and the driver fragment under test.

Single Driver Minimal Configuration​

First write the basic minimal configuration, then append the test fragment corresponding to the current driver mode after the basic configuration. [manual_stepper] still requires a minimal [printer] section (kinematics: none), which is simpler than a motion axis configuration and suitable for pure hardware verification.

Basic Minimal Configuration​

Use the basic minimal configuration from Hardware Testing Methods. If you copied a complete configuration from the quick test tool, it already includes [mcu] and [printer]; do not add them again. The examples below on this page are only appended fragments.

Driver Test Configuration Fragment​

Below only the driver test fragment to be appended is shown; do not add a second [printer] or [mcu].

[manual_stepper Drive0]
# Modify the following three items according to the actual mainboard pins
step_pin: PE2
dir_pin: PC5
enable_pin: !PF11
# No changes are needed for the parameters below
microsteps: 16
rotation_distance: 40
velocity: 500
accel: 10000
position_min: 0
position_max: 1000

[tmc2209 manual_stepper Drive0]
# Modify uart_pin according to the actual mainboard pin
# Modify sense_resistor according to the driver manufacturer's documentation
uart_pin: PC4
interpolate: False
run_current: 0.8
sense_resistor: <driver_sense_resistor>
stealthchop_threshold: 0
Configuration Notes
  • serial: Replace with the actual serial ID of the mainboard (can be viewed via ls /dev/serial/by-id/); keep only one instance in the basic minimal configuration.
  • step_pin / dir_pin / enable_pin: Replace with the mainboard pins corresponding to the driver port under test.
  • uart_pin (UART mode) / cs_pin + spi_bus (SPI mode): Replace with the actual pins and SPI bus number.
  • sense_resistor: Applies to the TMC2209 / TMC5160 in the examples; it must be filled in according to the parameters provided by the driver manufacturer—do not guess based solely on the chip model. Different TMC5160 driver boards may be 0.075, 0.033, 0.022, or other values; the TMC2240 test template uses SPI and rref—do not directly apply the TMC2209 UART example on this page or sense_resistor. If the manufacturer's documentation does not specify, please consult the manufacturer first or use their official configuration examples.
  • The configuration contains no heaters or fans; it is only used for driver communication verification.

Multi-Driver Testing Method​

If you need to verify multiple driver ports on a mainboard one by one, you can refer to the naming approach in the test configuration and write each driver port as an independent Drive0, Drive1, Drive2:

[manual_stepper Drive1]
step_pin: PE3
dir_pin: PF13
enable_pin: !PF14
microsteps: 16
rotation_distance: 40
velocity: 500
accel: 10000
position_min: 0
position_max: 1000

[tmc2209 manual_stepper Drive1]
uart_pin: PF12
interpolate: False
run_current: 0.8
sense_resistor: <driver_sense_resistor>
stealthchop_threshold: 0

During testing, only connect the motor to the driver port currently under test; after confirming one port, power off, then switch to the next port.

Test Steps​

  1. Save the basic minimal configuration and the current driver test fragment as printer.cfg.

  2. Confirm the motor and driver are properly inserted before powering on, then start Klipper.

  3. In the Mainsail / Fluidd console, enter the following commands to enable the motor and set the current position to 0:

    MANUAL_STEPPER STEPPER=Drive0 ENABLE=1
    MANUAL_STEPPER STEPPER=Drive0 SET_POSITION=0
    • If the motor has holding torque after enabling, enable_pin is basically working.
    • If the motor can still rotate freely, power off and check enable_pin, driver orientation, jumper caps, and power supply.
  4. Perform the manual movement test:

    MANUAL_STEPPER STEPPER=Drive0 MOVE=100 SPEED=100
    MANUAL_STEPPER STEPPER=Drive0 MOVE=0 SPEED=100
    • MOVE= is the target position, not a relative displacement. After executing MOVE=100, execute MOVE=0 and the motor will reverse back to the starting point.
    • If the motor is still connected to the machine's motion mechanism, it is recommended to first change the value to MOVE=10 SPEED=5 for the first test; after confirming the direction and travel are safe, increase the speed.
    • If the motor rotates smoothly without stuttering, the driver, motor, and pulse/direction pins are basically normal.
    • If the motor does not respond, only vibrates, or moves in the wrong direction, power off and check the pin configuration, motor wire order, driver orientation, and jumper caps.
  5. Verify TMC communication status:

    DUMP_TMC STEPPER=Drive0

    If register information is returned normally, UART/SPI communication is basically working; if it reports that registers cannot be read, please refer to TMC Error Troubleshooting.

  6. After testing, disable the motor:

    MANUAL_STEPPER STEPPER=Drive0 ENABLE=0

Expected Results​

Test ItemNormal ResultAbnormal Behavior
Manual movementMotor moves forward and backward according to commandsNo movement, vibration, stuttering, or wrong direction
TMC communicationDUMP_TMC returns register informationCannot read UART/SPI registers
Holding torqueAfter ENABLE=1, the motor shaft cannot rotate freelyShaft rotates easily (not enabled)

If all three items above are normal, the communication between the driver and mainboard and the motor wiring are fine; you can restore the original printer.cfg and continue troubleshooting other hardware.


CAN Toolhead Board Minimal Test​

Test Purpose​

Confirm that the CAN toolhead board has been recognized by Klipper, and verify the temperature, fan, accelerometer, or input port on the toolhead board.

Minimal Configuration​

First keep the basic minimal configuration, then append the following CAN toolhead board test fragment after the configuration. If you are only testing the CAN toolhead board, please also keep the mainboard [mcu] so that Klipper can start normally and display the mainboard connection status.

[mcu tool]
canbus_uuid: xxxxxxxxxxxx

[temperature_sensor ToolBoard]
sensor_type: temperature_mcu
sensor_mcu: tool

[output_pin tool_FAN0]
pin: tool:gpio13
pwm: True
cycle_time: 0.010
value: 0
shutdown_value: 0

Test Steps​

  1. Follow CAN Network Configuration and ID Search to search for and fill in canbus_uuid.
  2. After restarting Klipper, check whether the ToolBoard temperature displays normally.
  3. Use SET_PIN PIN=tool_FAN0 VALUE=1 to test the toolhead board's low-voltage fan output; after testing, execute SET_PIN PIN=tool_FAN0 VALUE=0.
  4. If you need to test the toolhead board's accelerometer or input port, add the configuration according to the corresponding section above.
CAN Troubleshooting Tips

CANH/CANL wire order, terminating resistors, jumper caps, and cable management must all be handled with the power off. Do not plug or unplug CAN cables or adjust terminating resistors while powered on.


Common Abnormalities and Next Steps​

Abnormal BehaviorCommon klippy.log KeywordsCheck FirstNext Step
Klipper cannot connect to MCUUnable to connect, Connect error, Serial connection closedserial / canbus_uuid, firmware, USB/CAN connectionCommon Error Overview
Abnormal temperature displayADC out of range, temperature, not heatingsensor_type, sensor_pin, thermistor connectorTemperature, Heating, and Extrusion Errors
Heater or bed shutdownVerify heater, not heating at expected rateThermistor contact, PID, heater power, SSRTemperature, Heating, and Extrusion Errors
Fan not spinningNo error (output ports do not generate logs)pin, fan voltage specification, PWM compatibilitySwap fan or port for cross-testing
Input state unchangedNo error (input ports do not generate logs)Pull-up ^, wire order, switch typeCheck connector and port with power off
Accelerometer no dataInvalid adxl345 id, Invalid lis2dw id, timeoutcs_pin, spi_bus, wiring harness, module modelAccelerometer Testing and Calibration
Resonance test failureNo data, Insufficient axis data, Frequency rangeSensor mounting, belt tension, fan vibrationAccelerometer Testing and Calibration
Motor not movingUnable to read tmc uart, Unable to write tmc spistep_pin, dir_pin, enable_pin, TMC configurationTMC Error Troubleshooting
TMC cannot read registersDRV_STATUS, read register, GSTATUART/SPI pins, jumper caps, driver power, driver modelTMC Error Troubleshooting
CAN toolhead board offlinebytes_invalid, Network is down, No buffer space, Timer too closeCAN wire order, terminating resistor, power, UUIDCAN Network Configuration and ID Search
Random stuttering/loss during printingStepper too far in past, Rescheduled timer, Lost communicationHost load, communication cable interference, speed/accelerationSystem, Performance, and Service Errors
Configuration cannot be savedUnable to write, Option conflict, CRC does not matchFile permissions, auto-save section conflicts, FIRMWARE_RESTARTConfiguration Errors

Reference Configuration Fragments​

When maintaining test configurations, you can extract fragments by hardware type from the corresponding mainboard/toolhead board templates:

  • Mainboard testing: temperature_sensor, manual_stepper DriveN, tmcXXXX manual_stepper DriveN, output_pin FANx, gcode_button IOx.
  • Toolhead board testing: temperature_sensor, adxl345 / lis2dw, manual_stepper Drive0, output_pin FANx, gcode_button.
  • Multi-driver testing: Keep the naming convention Drive0, Drive1, Drive2; the STEPPER= in test commands must match the configuration section names.
  • Low-voltage output testing: Prefer low-voltage loads such as fans, RGB, and buzzers; do not use heater cartridges or the heated bed as ordinary output_pin tests.

If a module cannot pass the above minimal tests, please restore the original configuration first, then continue troubleshooting on the corresponding FAQ page based on the specific error.

After completing the minimal tests, follow the steps to restore the formal configuration, then perform homing or printing.