Probe Calibration Tool
Klipper's probe Z offset, Z endstop, bed mesh, and Delta calibration commands all ultimately enter the same manual probing flow. It is provided by the manual_probe module, which Klipper loads automatically: it does not need to be written in printer.cfg and has no configurable options. What you actually configure is [probe] (or [bltouch]) and [stepper_z].
Most prompts from this flow are only waiting for you to enter TESTZ; they are not faults. Only the three below actually invalidate a calibration or prevent a command from starting.
Quick Reference
| Terminal prompt | Nature | What to do |
|---|---|---|
Starting manual Z probe… | Normal prompt, waiting for input | TESTZ Z=-0.1 to approach downward → ACCEPT; use ABORT to give up |
Manual probe failed!… | This calibration is void (no shutdown, no config write) | Re-run the calibration command; do not move X/Y at all, and the final Z must be lower than at the start |
Already in a manual Z probe… | Command-level error | ABORT the old session first, or end the other tool that holds ACCEPT |
Probe hardware and configuration errors (
Probe triggered prior to movement,No trigger on probe,Probe samples exceed samples_tolerance, BLTouch, bed_mesh) are covered in Motion, endstop, and leveling errors.
Which Commands Start Manual Probing
| Command | Purpose | Manual probing |
|---|---|---|
MANUAL_PROBE | Measure the Z of a point with the paper method when there is no probe | Always |
PROBE_CALIBRATE | Calibrate the probe z_offset | Fine adjustment after probing |
Z_ENDSTOP_CALIBRATE | Calibrate position_endstop | Always; only exists when [stepper_z] defines position_endstop, machines that use the probe as the Z endstop (probe:z_virtual_endstop, e.g. TAP) do not have this command |
DELTA_CALIBRATE | Delta tower height / radius | When there is no probe or METHOD=manual |
BED_MESH_CALIBRATE, BED_TILT_CALIBRATE, Z_TILT_ADJUST, QUAD_GANTRY_LEVEL | Bed mesh / tilt / multi-Z probing | When METHOD=manual is added |
The calibration dialog in Mainsail / Fluidd reads the manual_probe state; clicking ACCEPT is equivalent to entering ACCEPT in the terminal.
TESTZ Usage
| Form | Behavior |
|---|---|
TESTZ Z=-0.1 | Move by the given value, not limited by the step size (use it to close a large gap in one move) |
TESTZ Z=- / -- | Bisect / jump to a lower probed point, step ≤ 0.2mm |
TESTZ Z=+ / ++ | Bisect / jump to a higher probed point, step ≤ 0.2mm |
+/-/++/--move at most0.2mmper command; if that is too slow, use the numeric form.- Each
TESTZfirst lifts to "target + 0.5mm" and then descends to the target, so the nozzle rising slightly mid-move is normal.
The Three Prompts in Detail
Starting manual Z probe
// Starting manual Z probe. Use TESTZ to adjust position.
// Finish with ACCEPT or ABORT command.
// Z position: ?????? --> 5.000 <-- ??????
Normal prompt; the state is still ready, and it neither ends on its own nor times out. The value between --> and <-- is the current Z; the left and right sides are the lower / higher positions already probed, and ?????? means nothing has been recorded in that direction yet.
What to do: step down following the paper test flow, and ACCEPT on contact.
Manual probe failed!
// Manual probe failed! Use TESTZ commands to position the
// nozzle prior to running ACCEPT.
The calibration is void: no shutdown is triggered, but no configuration is written, ACCEPT / TESTZ / ABORT stop working, and the calibration command must be re-run (clicking SAVE_CONFIG at this point is meaningless).
There are only two causes, and either one fails it:
- X/Y moved: a joystick / arrow key was used during the session, or a macro contains
G1 X.. Y.., or Klicky's dock move. - Z was not lower: you only moved up, or probed too far down and lifted back to the starting point; the check only looks at Z at the moment
ACCEPTis pressed, regardless of the motion in between (even0.01mmhigher fails).
Resolution:
- Re-run the calibration command and approach in one direction, downward with
TESTZ Z=-0.1(-0.05when close); confirm the middleZ positionvalue is smaller than at the start, thenACCEPT. - Do not touch X/Y during the session.
- If it fails immediately every time, check whether the starting height is too low, depending on the structure:
- Machines with a dedicated Z endstop: check
[stepper_z] position_endstop. - Using the probe as the Z endstop (
probe:z_virtual_endstop, nozzle-triggered structures such as Voron TAP):[stepper_z]has noposition_endstop; check[probe] z_offsetand the Z axis lower limitposition_min. - Delta machines: also check
minimum_z_position.
- Machines with a dedicated Z endstop: check
Already in a manual Z probe
Already in a manual Z probe. Use ABORT to abort it.
Command-level error: before starting a new session, Klipper finds that ACCEPT is already taken.
Common causes: the previous session did not finish with ACCEPT / ABORT; tools such as BED_SCREWS_ADJUST also hold ACCEPT; a custom gcode_macro has the same name as a built-in command.
Resolution:
- Run
ABORTto end the old session. If it reportsUnknown command: ABORT, there is no session; end the tool that actually holdsACCEPTinstead (e.g. runADJUSTEDinBED_SCREWS_ADJUST). - If it happens every time, check all
includefiles for a macro with the same name as a built-in command, rename or delete it, and retry. - Refreshing the interface or restarting Klipper clears the stale calibration dialog in the UI.
After ACCEPT
MANUAL_PROBErepliesZ position is <value>;PROBE_CALIBRATEandZ_ENDSTOP_CALIBRATEgive a suggested new value.- You must run
SAVE_CONFIG(orSAVE_CONFIG & Restartin the interface) for the setting to be written and take effect after a restart. - To give up midway, use
ABORT: no configuration is written, andManual probe failed!is not triggered.
Standard Paper Test Flow
The nozzle moves down automatically during calibration. Before starting, move hands and tools away, make sure nothing obstructs below the nozzle and nothing is left on the heatbed, and be ready to emergency-stop at any time.
- Home the printer and move the nozzle directly above the point to calibrate.
- Run the calibration command and confirm that
Starting manual Z probeappears. - Place the paper between the nozzle and the heatbed and slide it back and forth.
- Lower it gradually with
TESTZ Z=-0.1; when close, switch toTESTZ Z=-0.05orZ=-for finer steps. - Stop when the paper is lightly pinched and drags with clear resistance.
- Run
ACCEPT; if it reportsManual probe failed!, troubleshoot per that entry and redo. - Run
SAVE_CONFIGto save and restart.
Always approach the contact point from above; this reduces Z axis backlash error and also avoids failing because Z is not lower than the starting height.