Klippain Shake&Tune Resonance Analysis Plugin

Klippain Shake&Tune is a Klipper resonance analysis and input shaping calibration plugin that generates visual charts from vibration data collected by accelerometers, helping to troubleshoot mechanical issues and optimize Input Shaper filters.

FlyOS-FAST Users

FlyOS-FAST v1.3.5 and above comes with Shake&Tune pre-installed, no manual installation is required. Simply add the [shaketune] configuration section to printer.cfg and restart to use it.

For complete configuration parameters and instructions, please refer to: FlyOS-FAST Shake&Tune Plugin Documentation

Installation

Use an SSH tool to connect to the host machine and confirm the following conditions:

  1. Klipper firmware is installed on the host machine.
  2. An accelerometer (ADXL345, LIS2DW, etc.) is installed and properly configured, and ACCELEROMETER_QUERY returns data normally.
  3. The [resonance_tester] section is defined in printer.cfg.

Pull or Update the Plugin

This step requires a connection to GitHub. After confirming the pull was successful, run the installation script.

cd ~
if [ -d ~/klippain-shaketune/.git ]; then
git -C ~/klippain-shaketune pull --ff-only
else
git clone https://github.com/Frix-x/klippain-shaketune.git ~/klippain-shaketune
fi

Run the Installation Script

cd ~/klippain-shaketune
chmod +x install.sh
./install.sh
systemctl restart klipper

If using the FlyOS-FAST system, the installation path should be adjusted to the /data/ directory. Please refer to the FlyOS-FAST specific documentation above for details.

Add Configuration Section

Add the following to printer.cfg:

[shaketune]
# result_folder: ~/printer_data/config/ShakeTune_results
# Path where processing results are saved; the folder is created automatically if it does not exist
# number_of_results_to_keep: 10
# Number of recent results to keep; old files are automatically cleaned up when exceeded
# keep_raw_data: False
# Set to True to also save the raw .stdata files, useful for troubleshooting or submitting feedback
# show_macros_in_webui: True
# Display Shake&Tune macro buttons in the Fluidd / Mainsail web interface
# timeout: 600
# Chart generation timeout in seconds; can be increased on low-performance devices

Save and restart Klipper.

Verify Installation

systemctl is-active klipper

After it returns active, enter macro commands such as TEST_RESONANCES in the web console to confirm the commands are recognized.

Available Macro Commands

After installation, the following macro commands are available in the web console or as G-code:

Macro CommandPurpose
TEST_RESONANCES AXIS=XMeasure X-axis resonance and generate spectrum charts with suggested Input Shaper parameters
TEST_RESONANCES AXIS=YMeasure Y-axis resonance and generate spectrum charts
TEST_RESONANCES AXIS=X OUTPUT=raw_dataOnly collect raw data without automatically generating charts
COMPARE_RESONANCESCompare the two most recent resonance measurements to observe the effect of adjustments
BELTS_SHAPER_TUNINGDedicated belt resonance test that generates a Hanning window spectrum comparison chart

After each execution, Shake&Tune generates PNG chart files in the result_folder, which can be viewed directly through the Fluidd / Mainsail file manager.

Differences from Built-in Klipper Commands

Shake&Tune does not replace Klipper's built-in SHAPER_CALIBRATE but provides richer visual analysis on top of it:

FeatureKlipper Built-inShake&Tune
Automatically calculates Input Shaper parametersSHAPER_CALIBRATE writes directly to the configurationTEST_RESONANCES generates charts for reference
Spectrum visualization chartsNoneAutomatically generates PNG spectrum charts
Belt tension comparisonNoneBELTS_SHAPER_TUNING generates comparison charts
Comparison of multiple measurementsNoneCOMPARE_RESONANCES compares recent results

Built-in commands are suitable for quick automatic calibration; Shake&Tune is suitable for scenarios where you need to view detailed spectrums, troubleshoot mechanical issues, or compare belt tension.

Common Issues

Chart Generation Timeout

Low-performance devices may time out when generating charts. Increase the timeout value in the [shaketune] section, for example: timeout: 900.

No Results Generated in the Result Folder

Confirm that the result_folder path exists and Klipper has write permissions.

ACCELEROMETER_QUERY Error After Installation

Shake&Tune does not affect the underlying accelerometer communication. If communication errors occur after installation, first troubleshoot the hardware and configuration according to Accelerometer Testing and Calibration.

Accelerometer Configuration and Testing: View Accelerometer Testing and Calibration

Resonance Compensation and Input Shaper Tuning: View Resonance Compensation and Pressure Advance Configuration Issues